Transmitters - Endress Hauser - 3

Transmitters - Endress Hauser - 3

Part Number: PMD230-WB2D4ED8B Features 230 psi Max Pressure 4-20 mA HART. SIL 2 inH 2 O calibration FKM Viton seal Oval flange with 7/ UNF. C 22.8 FM Intrinsically Safe. Class I,II,III, Div. 1, 1/ 2 NPT International Buyers- Please Note: Import duties. Taxes and charges are not included in the item price or shipping charges.
Get Price
Reasonable Design Signal Calibrator 0.075% High Accuracy ...

Reasonable Design Signal Calibrator 0.075% High Accuracy ...

Dec 26, 2021 · The EJA530A is the In-line mount Gauge Pressure Transmitters in the series. EJA530A features include: 0.2% Accuracy (0.075% Option) 0.1% Stability for 1 year. 8,500 psi MWP. Explore how the EJA530A can help you Boost your bottom line.
Get Price
Absolute & Gauge Pressure Transmitter - Pressure ...

Absolute & Gauge Pressure Transmitter - Pressure ...

accuracy: upto 0.075 % of adjusted span: process connections: threaded ½” bsp or npt male: turn down: 10:1: output: 4-20 ma 2-wire, option hart protocol, profibus pa: adjustment: with 3 push buttons and display, without test pressure: power supply: 12 - 36 vdc (ex: 12 - 26,5 vdc) protection: ip66 (option ip68) ambient temperature-20 °c ...
Get Price
Handheld Multifunction Calibrator w/ Pressure Modules

Handheld Multifunction Calibrator w/ Pressure Modules

Jan 28, 2021 · (High) Input only 0-250 V ac/dc Frequency: 0-1000.0 CPS, Hz 0-10.00 kHz Continuity: 0 to 400.0Ω audible tone under 10Ω Accuracy: T/C Type J: ±0.3°C ± 10µV (±0.6°C total error) mA Compliance: up to 1000 Ω Voltage Drive: 1 mA RTD IEX-range: 0.01 mA to 3 mA RTD Frequency Response: 10 mS Operating Temp:-10 to 50°C Storage Temp:-40 to 60°C
Get Price
Portable Pressure Calibrator with Internal Pressure Source

Portable Pressure Calibrator with Internal Pressure Source

Oct 13, 2021 · The PCL-5100, a low-pressure unit with ranges from 30 inHG to 100 psi, offers five independent selectable ranges. Specifically designed for rugged field usage, it weighs less than 25 pounds and has its own built-in pressure and vacuum source. SPECIFICATIONS. Overall Accuracy: ±0.05% FS Max.
Get Price
Extech 412300A-NIST Milliamp Calibrators - Current ...

Extech 412300A-NIST Milliamp Calibrators - Current ...

Accuracy (of reading) ± (0.075% + 1 digit) or ± 3 digits, Whichever is greater: Meter Power: 9 volt battery or AC adaptor: Loop Power: 12V DC (412300A only) Maximum Load: 350 ohms at 20 mA: Dimensions: 3.8 x 4.2 x 1.8" (96 x 108 x 45mm) folded: Weight: 12 oz. (340g) Accessories Supplied: 9V battery, calibration cable with spade lugs, carrying case, 110V AC adaptor
Get Price
056.P.N:Layout 2 8/18/10 8:26 AM Page 1 Explosion-proof ...

056.P.N:Layout 2 8/18/10 8:26 AM Page 1 Explosion-proof ...

(no calibrator required) • Rangeability (100:1) • High accuracy (0.075%) • Automatic ambient temperature compensation • Fail-mode process function • Selectable engineering units APPLICATIONS • Flow measurement • Level monitoring • Filter or pump differential pressure • Critical process monitoring Model 3100D-2-FM-1-1 3100D-3 ...
Get Price
Fundamentals of Instrumentation, Process Control, PLCs and ...

Fundamentals of Instrumentation, Process Control, PLCs and ...

This eliminates the pressure drop across the meter and also the force required driving the gear. This eliminates the force, which causes the slip flow. This mainly applies to smaller sized meters and significantly increases the accuracy at low flows. Advantages. High accuracy of 0.25%; High operating pressures, up to 10MPa; High temperatures ...
Get Price
Signal Calibrators | TEquipment

Signal Calibrators | TEquipment

Imagine testing a tank level situation. With a mA calibrator, it is safe to simulate a 90% full condition to test a high alarm warning and 95% to test the high high alarm. Another safety example is simulating a high pH mA signal to trigger shutdown of pumps sending water into the sewer. “I think we have a bad valve…”
Get Price
Automation - Locations worldwide | JUMO

Automation - Locations worldwide | JUMO

Calibration accuracy ± 0.05 % ± 0.075 % ± 0.2 % ± 0.3 % Galvanic isolation 2 kV 50 V (triple isolation) – Up to 3.7 kV (against voltage supply) Special features Customer-specific linearization Universal transmitter, customer-specific linearization, open-collector output, alarm output Analog signal path, can be digitally adjusted
Get Price
Explosion Proof Differential Pressure Transmitter ...

Explosion Proof Differential Pressure Transmitter ...

High accuracy up to ±0.075%. Automatic ambient temperature compensation improves performance of device. It can be used as flow meter and should be installed vertically without using additional flanges. Various Output: 4-20 mA, digital signals. The mounting bracket can be rotated up to 360º and LCD display up to 270º.
Get Price
Voltage calibrator, Voltage calibration equipment - All ...

Voltage calibrator, Voltage calibration equipment - All ...

SUP-825-J Signal Calibrator 0.075% high accuracy 0.075% Accuracy signal generator has a multiple signal Output and measurement including voltage, current and thermoelectric couple with LCD screen and ...
Get Price
Calibrators - Druck Dpi

Calibrators - Druck Dpi

The cost effective GE Druck DPI 603 pressure calibrator. Which extends the GE Druck range of rugged portable battery powered pressure calibrators, has standard ranges of-1 to +1 bar, 2 bar, 10 bar, or 20 bar gauge with an accuracy of ±0.075% Designed for use in remote locations where AC power is not available.
Get Price
Extech 412300A Current Calibrator/Meter | TEquipment

Extech 412300A Current Calibrator/Meter | TEquipment

Apr 17, 2015 · The screen can show measuring currents readings as a percentage of to 0 to 24 mA range (4-20mA = 0-100.0% or either in a reading in mA (up to 0.01mA) in voltage rangers. The accuracy of the device is unlike any that can be seen on other device, it has an accuracy of 0.075%, which is considered extremely high.
Get Price
Temperature calibrator - SUP-825-J - Supmea Automation ...

Temperature calibrator - SUP-825-J - Supmea Automation ...

SUP-825-J Signal Calibrator 0.075% high accuracy 0.075% Accuracy signal generator has a multiple signal Output and measurement including voltage, current and thermoelectric couple with LCD screen and silicone keypad, simple operation, longer standby time, higher accuracy and programmable output.
Get Price
Extech 412355A Current and Voltage Calibrator/Meter ...

Extech 412355A Current and Voltage Calibrator/Meter ...

High accuracy 0.075% Oyster case with flip-up display is ideal for handheld or benchtop applications Large LCD displays readings in mA (to 0.01mA) or as a percentage of the 0-24mA range (4-20mA = 0-100.0%) or as mV in voltage ranges
Get Price
Humidity calibrator - All industrial manufacturers

Humidity calibrator - All industrial manufacturers

SUP-825-J Signal Calibrator 0.075% high accuracy 0.075% Accuracy signal generator has a multiple signal Output and measurement including voltage, current and thermoelectric couple with LCD screen and silicone keypad, ...
Get Price
Extech 412300A Current Calibrator/Meter | TEquipment

Extech 412300A Current Calibrator/Meter | TEquipment

Apr 17, 2015 · The accuracy of the device is unlike any that can be seen on other device, it has an accuracy of 0.075%, which is considered extremely high. It has also been programmed with five preset calibration values for fast calibration calculations in the field for efficient working.
Get Price
Fluke 750P Series Pressure Modules | Fluke

Fluke 750P Series Pressure Modules | Fluke

Oct 28, 2019 · Fluke 750P Series Pressure Modules will turn your Fluke multifunction calibrator into a full-fledged pressure calibrator. These flexible modules not only work with multifunction calibrators like the 725, 726 or 750 Series Calibrators but also extend the measurement range of Fluke pressure calibrators.Since the pressure modules are calibrated independently, they can …
Get Price
940A Thermocouple Calibrator | TEGAM | Temperature Calibrators

940A Thermocouple Calibrator | TEGAM | Temperature Calibrators

TEGAM's 940A handheld, digital Thermocouple Calibrator offer 500 hours of battery life, lab-grade accuracy, simultaneous Source & Measure, and function with four thermocouple probe types. Used in Aerospace, Food Industry, Automotive, Plastics and Chemical applications needing temperature calibrators. View and buy online.
Get Price
Rosemount Pressure Transmitter Model …

Rosemount Pressure Transmitter Model …

The Coplanar™ platform creates a flexible interface for multiple process connections for your pressure, flow, and level applications. The flexible design reduces engineering and installed costs. WITH XXXXX 4663286 SIHS03.
Get Price
JOFRA Temperature Calibrators - AMETEK CALIBRATION

JOFRA Temperature Calibrators - AMETEK CALIBRATION

Temperature Calibrators. Our dry-block and liquid bath portable temperature calibrators include 6 series with more than 25 models and temperature ranges from -100 to 1205°C. All feature portability, accuracy, speed, and advanced documenting functions with JofraCal calibration software. Our calibrators include the smallest and coldest dry-block ...
Get Price
Fluke 714B Thermocouple Calibrator | Fluke

Fluke 714B Thermocouple Calibrator | Fluke

High accuracy thermocouple temperature calibration the easy way Fluke 714B is a handheld, battery-operated instrument that measures and sources a variety of thermocouple types and millivolts. It can calibrate a linear thermocouple transmitter with the mV source function and also measure mA while sourcing temperature.