Home > Greece Complete Specifications Modbus Ph Sensor

Greece Complete Specifications Modbus Ph Sensor

Just fill in the form below, click submit, you will get the price list, and we will contact you within one working day. Please also feel free to contact us via email or phone. (* is required).
Sentron Measuring Devices and Power Monitoring Complete ...

Sentron Measuring Devices and Power Monitoring Complete ...

† Easy integration of existing modbus-capable measuring devices † Communication through Standard Ethernet † Integration of devices with RS 485 interface (ModbusRTU) through Modbus gateway, e.g. the 7KM PAC4200 measuring device can be used as the gateway Industries The energy efficiency that can be achieved with consistent
Get Price
Snap In Front Panel Programmer with Modbus over RS-485

Snap In Front Panel Programmer with Modbus over RS-485

The unit converts a wide array of sensors and analog device signals like uni- and bipolar mA and voltage signals, potentiometer, Lin. R, RTD and TC, to a Modbus communication line signal. All individual unit operating parameters can easily and quickly be configured by using the Modbus communication or by using the front display menu.
Get Price
industrial-Grade-pH-Sensor-MODBUS-RTU-RS485 - Seeed Studio

industrial-Grade-pH-Sensor-MODBUS-RTU-RS485 - Seeed Studio

SKU This industrial-grade MODBUS-RTU RS485 pH meter/sensor features ATC, low-power-consumption, high integration. It can be widely used in monitoring pH levels in soil and water applications such as agriculture, gardening, horticulture, swimming pools, scientific experiments, and other environmental monitoring scenarios. $139.00
Get Price
RS485 & 4-20mA Current pH Sensor User Manual

RS485 & 4-20mA Current pH Sensor User Manual

RS485 & 4-20mA Current pH Sensor User Manual Product Model: S-pH-01 Version: V1.0 . ... 2 Specifications pH Range 0 to 14 pH Accuracy ±0.1 pH Resolution 0.01 pH General Parameters ... It has a wide range of applications in smart sensors. The Modbus protocol is a master-slave architecture protocol. There is a master node, and other nodes that ...
Get Price
Hydrolab DS5X, DS5, and MS5 Water Quality Multiprobes

Hydrolab DS5X, DS5, and MS5 Water Quality Multiprobes

5 Section 1 Specifications Specifications are subject to change without notice. DS5 and DS5X Transmitter Outer Diameter 8.9 cm (3.5 in.) Length 58.4 cm (23 in.) Weight (typical configuration) 3.35 kg (7.4 lb) Maximum Depth 225 m Operating Temperature –5 to 50 °C Battery Supply (optional) 8 C batteries Computer Interface RS232, SDI-12, RS485 Memory (optional) 120,000 …
Get Price
SenseCAP ORCH S4 4-In-1 Weather Sensors (A1A), Air ...

SenseCAP ORCH S4 4-In-1 Weather Sensors (A1A), Air ...

ORCH S4 is an all-in-one compact weather instrument providing parameters of air temperature, humidity, barometric pressure, and light intensity supporting both MODBUS and SDI-12 and a power voltage from 3.6V to 16V.
Get Price
ASTI >> Industrial pH, ORP, Ion Selective & Conductivity ...

ASTI >> Industrial pH, ORP, Ion Selective & Conductivity ...

1MF-3EA-HiQ4FP-HiQDT-4EA-SCG-PS12 Triple Input Bridge Box with integral 12VDC power supply to energize sensors for 85 to 265 VAC line powered operation with PNCE-HiQDT-WPC Slurry, Sulfide & Extreme Dehydration Resistant Submersible RS-485 MODBUS RTU Smart pH Sensor with waterproofing style “C” sealing option on left and PN 6353-HiQDT-STUB Immersion …
Get Price
ATI Q46H | INDOHITECH

ATI Q46H | INDOHITECH

The pH reading can also be sent to one of the analog outputs for complete pH + chlorine monitoring. The pH correction can be done using ATI’s optional pH sensor or using an input signal of.0 VDC (4- 20 mA across a 100 ohm resistor) from another pH monitor. Input from another monitor requires the use of a loop isolator.
Get Price
MemoRail Modbus - M4 Knick

MemoRail Modbus - M4 Knick

MemoRail Modbus is a compact, digital analyzer available as 1-channel (A-1405N-P2-110) or 2-channel version (A-1405N-P2-210) for connection and operation of digital Memosens sensors for the process variables pH, ORP, conductivity, and oxygen, as well as for use with an optical oxygen sensor. Up to 31 devices can be operated in parallel on the Modbus RTU.
Get Price
3WL1 Air Circuit Breakers - Siemens

3WL1 Air Circuit Breakers - Siemens

Siemens · 10/2015 3 3WL1 Air Circuit Breakers Introduction Breaking capacity * Designations according to IEC, Appendix K. 1) Size II with I n max ≤ 2500 A. 2) Size II with I n max = 3200 A and In max = 4000 A. 3) At a rated voltage of ≥ 690 V, the I cw value of the circuit breaker cannot be greater than the Icu or Ics value at 690 V. 4) Rated operational voltage U
Get Price
pH Sensor (S-pH-01) User Guide

pH Sensor (S-pH-01) User Guide

Specifications Output Interface Analog Voltage 0-2V (Output resistance ~0ohm) RS485 Modbus-RTU ... Modbus-RTU PH range: 0-14PH PH= (REGISTER VALUE)/100.When REGISTER ... Following modbus function code are supported by sensor. Modbus Function ode 0x03 : used for reading holding register.
Get Price
TETHYS

TETHYS

Optional pipe mounting brackets. Dimensions. 140 x 140 x 91 mm. Weight. 2 kg approx. The EL200 is a configurable water controller that can adapt to many different probes and configurations, mono or multi-channel, among pH, ORP, dissolved oxygen, conductivity, chlorine, turbidity, total suspended solid (TSS) and temperature.
Get Price
Aqua TROLL 600 Operator’s Manual

Aqua TROLL 600 Operator’s Manual

Sensor Specifications Sensor Summary Sensors Shelf Life Field Life Recommended Calibraiton Frequency Pressure Rating - PSI Usable Depth Operational Temperature Range pH/ORP 15 months 1 year or greater 10 to 12 weeks 350 200 650 - 5 to 50° C RDO NA 2 years or greater 12 months 350 200 650 - 5 to 50° C Conductivity NA 2 years or greater User ...
Get Price
3/4-inchCombinationpHandORPSensorKits pH ORP

3/4-inchCombinationpHandORPSensorKits pH ORP

The pH sensor shall be available in convertible, insertion ... The sensor shall communicate via MODBUS ... All PC sc and RC sc 3/4-inch combination sensors come complete with an integral 4.5 m (15 ft.) sensor cable, Digital Gateway, and 1 m (3.3 ft.) digital extension cable.
Get Price
O & M Manual

O & M Manual

measuring node is a complete sensor and Modbus transmitter with submersible multi-pin connector on the back. If only one sensor is used, that sensor is connected directly to the controller. If more than one sensor is used, sensors plug into a multi-sensor bus bar, which is then connected to the controller.
Get Price
General SENCOM FU20F / FU24F / SC25F Specifications

General SENCOM FU20F / FU24F / SC25F Specifications

ph-orp/sencom-digital-sensor-communication.htm SENCOM® sensors maintain specific measurement and calibration data on an integrated chip along that is an integral part of the sensor. This data can be exchanged between the sensor and either a process transmitter (FLEXA), or a laboratory PC using the SENCOM® SPS24 data management software.
Get Price
pH ARC SENSORS - Insatech

pH ARC SENSORS - Insatech

The digital RS485 interface enables communication with pH ARC sensor for performing measurements, for calibrating the sensor and for changing the sensor’s configuration parameters. pH ARC sensors are always connected to digital controlling devices as a Modbus slave. To function, they require a
Get Price
Liquiline CM442/CM444/CM448 Technical Information

Liquiline CM442/CM444/CM448 Technical Information

Measuring point pH value or ORP A complete measuring system comprises: • Liquiline transmitter ... Modbus TCP, 4 x relays for cleaning/limit value, 2 x analog current input ... pH glass sensor • Outputs and relays are named according to their function, …
Get Price
pH Hamilton - CerCell

pH Hamilton - CerCell

OneFerm pH sensor manufactured by Hamilton are available with 3-10 pH range and type S8 or K9 or VP8 connector. High precision measurement with specifications of +/- 0.15 pH and +6 month workable lifetime. Sensor shelf life / dry storage pre-installed in SUB/SUF are +12 month. Need less than 1 hour conditioning in media before one point ...
Get Price
Sensor for fast ammonium and nitrate measurement | Endress ...

Sensor for fast ammonium and nitrate measurement | Endress ...

ISEmax CAS40D is the right technology for trend measurement directly in the basin. It helps you to increase the efficiency and reduce the energy costs of your aeration processes. The sensor works without reagents saving you even further money. With its robust ion-selective membranes and excellent self-cleaning, it eases your maintenance tasks.
Get Price
PH Indicator Controller with Sensor, पीएच नियंत्रक ...

PH Indicator Controller with Sensor, पीएच नियंत्रक ...

Front Panel calibration of pH-4 and pH-7. Optional printer interfacing. Panel Mounting flame-proof enclosure. FDA 21 CFR part 11 - GAMP-4 compatible; Micro controller based indicator with inbuilt DP measurement; Incorporates highly stable built-in or DP sensor. (with different unit like mmwc/ pa/ kpa/ mmhg) 3 Digit, 0.56" bright LED display for ...
Get Price
industrial-Grade-pH-Sensor-MODBUS-RTU-RS485 - Seeed Studio

industrial-Grade-pH-Sensor-MODBUS-RTU-RS485 - Seeed Studio

This industrial-grade MODBUS-RTU RS485 pH meter/sensor features ATC, low-power-consumption, high integration. It can be widely used in monitoring pH levels in soil and water applications such as agriculture, gardening, horticulture, swimming pools, scientific experiments, and other environmental monitoring scenarios. Comes with a waterproof aviation connector, …
Get Price
W600 Series Water Treatment Controller - Walchem

W600 Series Water Treatment Controller - Walchem

The W600 series provides reliable, flexible and powerful control for. your water treatment program. Controls up to 6 complex functions. Touch screen display with icon-based programming makes setup easy. Analytical sensors measuring pH, ORP, conductivity, disinfection, fluorescence and flow meter input.
Get Price